DeDietrich G130 Bedienungsanleitung Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
GAS ADJUSTMENT
Z
ELECTRICAL CONNECTION
2
1
3
4
5
L
N
A
CAUTION
the appliance must be earthed. The yellow-green wire must be
connected to the earth. The manufacture declines all responsability
for any accident caused by failure to comply with this instructions
Conversion to LPG
Always isolate the cooker from the electricity supply, turn off the
gas supply temporarily and proceed as follows.
- change the injectors,
- adjust the minimum flow of the burners.
REPLACEMENT OF WORK-TOP INJECTORS
In order to change the work-top injectors, it is necessary to act as
follows: remove the grids, remove burners and flame-spreaders
(see fig.A), change the injector (see fig.B) and replace it with
another one suitable for the new type of gas (see table D). Re-
assemble everything in the opposite direction, paying attention to
place the flame-spreader in the right way on the burner.
AB
Fig. 4 Fig. 5
MINIMUM FLOW ADJUSTMENT FOR WORK-TOP TAPS
In order to adjust the minimum, act as follows: switch the burner
on, and turn the knob towards the minimum flow position .
Remove the knob from the tap, introduce a little screwdriver in
the tap rod (fig. 4).
Attention: in taps with security valve, the minimum adjusting screw
Z is placed outside the rod tap (fig. 5).
Unscrew the adjusting screw in order to increase the flow or screw
it to decrease the flow.
The right adjustment is obtained when the flame has a length of
about 3 or 4 mm.
For butane/propane gas, the adjusting screw must be tight screwed.
Make sure that the flame does not go out passing quickly from
the max. flow to the minimum flow .
Assemble the knob again.
IMPORTANT
The wires in the mains lead are coloured in accordance with the
following code:
GREEN AND YELLOW .....EARTH
BLUE .................................NEUTRAL
BROWN.............................LIVE
REPLACEMENT OF THE CABLE
In case the cable is damaged, replace it in accordance with the
following instructions:
- open the box of the supply board as described on the picture
below;
- unscrew screw A fixing the cable;
- replace the cable with one of the same lenght and in accordance
with the features described on the table; switch the appliance
off, and close the gas tap
- the green-yellow earth wire must be connected to the terminal
and it must be about 10 mm longer thean the live wires;
- the blue neutral wire must be connected to the terminal marked
with letter N;
- the live wire must be connected to the terminal marked with letter
L.
This appliance must be installed by a qualified person in
accordance with the latest edition of the IEE Regulations and
in compliance with the manufacturer instructions.
Ensure that the voltage is the same as that stated on the rating
plate. The rating plate which can be found on the inside of the
front appliance drawer.
WARNING! THIS APPLIANCE MUST BE EARTHED
If an fixed appliance is not equipped with supply cable and plug,
the power supply must be fitted with a disconnect switch in which
the distance between contacts permits total disconnection in
accordance with overvoltage category III, as required by installation
regulations.
Be sure that the earth wire green/yellow is not interrupted
by the switch
Cable type HO5 RRF 3 X 1.5 mm
2
Connecting the mains cable
Open the mains terminal block cover as shown, unscrew screw
A the cable clamp and unscrew (not fully) the screws in the
mains terminal block L N E which secure the three wires of the
mains cable. Fit the cable and refit screw A the cable clamp.
Allow sufficient cable length for the cooker to be pulled out for
cleaning, but do not let it hang closer than 50mm (2) to the floor.
The cable can be looped if necessary, but make sure that it is not
kinked or trapped when the cooker is in position.
17
Values referred to Hs - 15°C - 1013,25mbar
TAB. D
Cat. II 2H3+
GENERAL INJECTORS TABLE
Kind of gas
mbar
Nozzle
Burners
Power
KW Consum
N° max. min. max. min.
115
Rapide
3,00 0,75 286 l/h 72 l/h reg.
NATURAL 20 97
Semi rapide
1,75 0,48 167 l/h 46 l/h reg.
G 20 72
Auxiliary
1,00 0,33 95 l/h 31 l/h reg.
130
Triple crown
3,60 1,30 343 l/h 124 l/h reg.
BUTANE 28-30 85
Rapide
3,00 0,75 219 g/h 55 g/h 42
G 30 65
Semi rapide
1,75 0,48 128 g/h 35 g/h 31
50
Auxiliary
1,00 0,33 73 g/h 24 g/h 27
PROPANE 37 96
Triple crown
3,60 1,30 262 g/h 95 g/h 60
G 31
By pass
GB
Seitenansicht 16