DTG(E)130 - 35/45/65/90/115 Eco.NOxPlus 15/02/2011 - 300014279-001-J
16. Chimney sweep instructions
16 Chimney sweep instructions
Setting the boiler output for measuring emissions
` Tilt the flap on the control panel
.
` Press key
%O
and
$P
simultaneously for 2 seconds
.
` Use keys + and - to switch from
to
-
:
Maximum boiler output
-
:
Minimum output
` In the display area:
EMISSION MES. 88.8°: Boiler temperature
EMISSION MES. 8888: Fan speed
EMISSION MES. 88.8uA: Ionization current
DTGE130-35,
DTG130-35
DTG130-45 DTG130-65 DTG130-90 DTG130-115
Fan speed (rpm) 1100 1100 1200 1200 1300
Ionization current (µA) 44444
Fan speed (rpm) (Natural gas) 4600 5200 5200 6200 7000
Fan speed (rpm) (Propane) 4200 4600 4600 6100 6700
Ionization current (µA) 99999